Calculator › How to calculate a U-value
How to calculate a U-value
The U-value (thermal transmittance) is the heat flow through one square metre of construction per degree of temperature difference. The lower the U-value, the better the insulation.
The formula
U = 1 / RT · RT = Rsi + ΣR + Rse
U is in W/(m²·K). ΣR is the sum of the layers (see how to calculate the R-value). Rsi and Rse are the internal and external surface resistances (EN ISO 6946):
| Heat flow | Example | Rsi | Rse |
|---|---|---|---|
| Horizontal | Wall | 0.13 | 0.04 |
| Upwards | Roof | 0.10 | 0.04 |
| Downwards | Floor | 0.17 | 0.04 |
With a ventilated façade or a tiled roof, Rse = Rsi and the layers outside the ventilated cavity are ignored.
Worked example
The externally insulated wall from the R-value example has ΣR = 5.18 m²·K/W:
RT = 0.13 + 5.18 + 0.04 = 5.35 → U = 1 / 5.35 = 0.19 W/(m²·K)
Corrections
- Timber studs or joists in the insulation layer: use parallel paths through timber and insulation (EN ISO 6946) or a 2D calculation.
- Fixings (wall ties, anchors) that penetrate the insulation: add a correction ΔU.
- Ground floors and floors over a crawl space: the ground adds insulation (EN ISO 13370).
Typical requirements
Belgium (EPB): U ≤ 0.24 W/(m²·K) for walls, roofs and floors. Germany (GEG, when renovating): U ≤ 0.24 for external walls and pitched roofs, 0.20 for flat roofs. Passive house guideline: U ≤ 0.15.
Isolator is a free, independent alternative to established building-physics calculators such as Ubakus: build your wall, roof or floor layer by layer and instantly see the U-value, condensation risk and summer performance – no account, right in your browser. What sets Isolator apart: compare variants side by side to see which build-up performs best, check them straight against building regulations and calculate with the λ-values that apply in your country.