Isolator
U-value, R-value & condensation calculator

Calculator › Internal wall insulation for solid walls

Internal wall insulation for solid walls

Solid walls without a cavity, or a facade that must not change (listed building, conservation area)? Then insulating on the inside is what remains. It works, but it needs more care than other insulation: the masonry gets colder, and moisture has to go somewhere.

Worked example: a solid brick wall

Solid brick wall of 330 mm with lime plaster inside. Against it goes a stud wall with 60 mm glass wool (λ 0.035) and plasterboard.

OptionUCondensation (Glaser)WTA 6-4
Uninsulated1.68––
60 mm glass wool, no vapour control0.428.0 kg/m², does not dry outfails
60 mm glass wool + vapour control sd 2 m0.420.30 kg/m², dries in 45 dayspasses
60 mm glass wool + smart (variable) membrane0.420.14 kg/m², dries in 12 dayspasses
60 mm glass wool + polythene (sd 50 m)0.42nonetoo vapour-tight

U in W/m²·K. Heat loss through the wall drops to a quarter, whichever membrane you choose. The difference between the options is not the insulation value but what happens to moisture.

Open this example in the calculator →

Why internal insulation is a moisture question

Without insulation the house heats the wall, and it dries easily. With insulation on the inside the brickwork stays cold in winter. Water vapour from the house that passes through the insulation condenses against the old wall. Without vapour control that is 8 litres of water per m² per winter in this example, more than can dry out in summer.

Tight, but not too tight

The reflex is polythene, as vapour-tight as possible. Glaser then shows no condensation. But a solid wall also gets wet from the outside through driving rain and must be able to dry partly to the inside in summer. That is why the German WTA guideline 6-4, the common design rule for internal insulation, sets two limits:

A smart, humidity-variable membrane fits best: it restricts vapour in winter and lets moisture through in summer. In the example the wall dries fastest with it.

Limits of the simple check

Capillary-active boards

Calcium silicate and similar boards work without a membrane: they absorb condensate and wick it back to the room. 60 mm of calcium silicate reaches U 0.63 on this wall, less than glass wool because the material insulates less per centimetre (λ ≈ 0.06). Glaser and the simplified WTA check cannot assess this behaviour, and the calculator says so. Follow the manufacturer's system guidance or have a simulation done.

Things to watch

In the calculator choose Wall and put the insulation on the inside of the masonry. The moisture check then shows the WTA 6-4 test automatically, with the limits for your insulation thickness and wall.

Isolator is a free, independent alternative to established building-physics calculators such as Ubakus: build your wall, roof or floor layer by layer and instantly see the U-value, condensation risk and summer performance – no account, right in your browser. What sets Isolator apart: compare variants side by side to see which build-up performs best, check them straight against building regulations and calculate with the λ-values that apply in your country.

Open the free calculator →